Cells on a Line
Spray Line 1 isn't one machine. Parts go through a pump that feeds the coating, a spray booth where the nozzles apply it, and a curing oven that sets it. When the line stops, the question an engineer asks next is which one stopped it?
In Kanoa, the pieces of equipment that make up a line are cells: assets of type Cell under the line. In this lesson you'll keep OEE on Spray Line 1 and use cells to record which part of the line caused each stop:
- The stop still counts against Spray Line 1's availability, as one line with one OEE.
- Each stop also records the cell that caused it, with one of that cell's own states.
| Cell | What it does | Its downtime states |
|---|---|---|
Spray Pump | Feeds the coating to the booth | Pump Pressure Fault |
Spray Booth | Applies the coating through the nozzles | Spray Nozzle Clog, Cleaning |
Curing Oven | Cures the coating | Temperature Out of Range |
These are the Spray Line 1 states you created in Configure States. Each one belongs to a single piece of the line, so each moves to its cell.
This lesson uses one OEE for the line, with stops by cell. A plant can also OEE Enable each cell, with its own states, counts and runs, when it wants OEE for each piece of equipment. Then only the cell that makes the item should count outfeed, so the item's production isn't counted once per cell.
Create the Cells
- Navigate to Configuration → Ops → Assets.
- Select
CoreForge\Philadelphia\Coating\Spray Line 1in the tree and click + (Add Asset). - Enter
Spray Pumpas the Asset Name, set the Asset Type to Cell, and click the save icon. Leave OEE Enabled off: the cell's stops count against the line. - Select Spray Line 1 again and add
Spray BoothandCuring Oventhe same way.
The tree now shows the three cells under Spray Line 1:
Coating
└── Spray Line 1
├── Spray Pump
├── Spray Booth
└── Curing Oven
Link Each Cell's States
A stop recorded against a cell uses one of that cell's states. Link each state to the cell it belongs to, the same way you linked them to Spray Line 1.
- Select the States tab, then the Asset Links tab.
- Select
Spray Pumpand, holding the CTRL key, also selectPump Pressure Fault. Click the Link button. - Select
Spray Boothand, holding CTRL,Spray Nozzle ClogandCleaning. Click Link. - Select
Curing Ovenand, holding CTRL,Temperature Out of Range. Click Link.
Leave the states linked to Spray Line 1 as well. A stop that isn't any one cell's fault is still coded on the line.
Code a Stop to the Cell That Caused It
Spray Line 1's simulator stops the line now and then, and records each stop on the line. Here you'll do what an operator or supervisor does after a stop: say which cell caused it, and why.
- Click Home, then
Spray Line 1on the Asset Overview dashboard to open its Asset Operation screen. - Tap the Downtime tile. The Downtime Editor lists Spray Line 1's states.
- Select a downtime stop and click the edit button (✎). The Edit Events popup opens.
- In Asset, select
Spray Booth. - Click the edit button next to the state, select
Mechanical\Nozzle\Spray Nozzle Clogin the tree, and click Select. - Add a comment if you like, such as Nozzle 3 blocked, cleaned and restarted, and click Update.
The stop is marked as updated. It's still a Spray Line 1 stop, so it still counts against the line's availability, and now it also records that Spray Booth caused it, with a Spray Booth state.

From the PLC
Coding stops by hand works for a few stops a shift. On a real line, the PLC usually knows which cell stopped the line. Kanoa's data interface tag has a Machine ID input for this: when a cell stops the line, the PLC sets Machine ID to the cell's asset ID and State to the code linking that cell to its state. The stop is then recorded on the line with the cell's state, with nobody having to code it.